Elevator Maintenance Checklist: Monthly, Quarterly, and Yearly Tasks Your Contractor Should Be Performing
One of the most common questions I get from building owners and property managers across Ontario is some variation of: “How do I know if my elevator contractor is actually doing what they’re supposed to be doing?” It’s a fair question, and the fact that it comes up so often tells me something about the state of the industry. Too many building owners are paying for a maintenance contract and simply trusting that the work is being done — without any real way to verify it. And too many elevator contractors, frankly, are taking advantage of that trust.
I’ve been in this business for over 40 years. I started on the tools, became a Professional Engineer and a licensed Class A elevator mechanic, grew a company from 8 employees to 70, and now run Elevator One, which is consistently rated as one of the top elevator maintenance contractors in Ontario by the TSSA. I’ve seen the full spectrum of maintenance quality in this industry — from contractors who do meticulous, thorough work on every visit, to contractors who pull up to the building, sign the log book, and leave without opening a single panel. The difference in outcomes for the building owner is enormous: the well-maintained elevator runs reliably for 25 or 30 years with minimal breakdowns, while the neglected one eats up repair budgets, fails TSSA inspections, and needs a premature modernization that costs hundreds of thousands of dollars.
The purpose of this article is to give you a detailed, insider’s look at what should actually be happening during your elevator’s maintenance visits — broken down by monthly, quarterly, and annual tasks. This isn’t a simplified marketing checklist. It’s the real work that competent technicians do on properly maintained commercial elevators in Ontario. My hope is that it will give you the knowledge you need to have informed conversations with your elevator contractor and, if necessary, to hold them accountable for the service you’re paying for.
A Note Before We Begin: Every Elevator Is Different
Before diving into specifics, I need to make an important caveat. The exact maintenance requirements for any given elevator depend on the type of system (hydraulic, traction, or machine-room-less), its age, its usage intensity, the building environment, and the manufacturer’s specific maintenance recommendations. What I’m providing here is a comprehensive general framework based on decades of experience maintaining hundreds of elevators across every building type. Your specific elevator may require additional tasks or different intervals based on its particular configuration and operating conditions. A good maintenance contractor will customize their program to your equipment — not apply a one-size-fits-all template.
That said, the categories and types of work described below apply broadly to virtually all commercial elevator systems in Ontario, and if your contractor isn’t performing most of these tasks at the indicated intervals, you have reason to ask questions.
Monthly Maintenance Tasks
Monthly visits form the backbone of a preventive maintenance program. These are the tasks that need to happen regularly to catch wear and developing problems before they turn into breakdowns or safety hazards. A proper monthly maintenance visit on a typical commercial elevator should take at minimum an hour per elevator, and often longer depending on what the technician finds. If your contractor’s technician is consistently in and out of your building in 20 or 30 minutes, the work isn’t being done thoroughly.
The door system is the highest-priority area during monthly maintenance, and for good reason: door-related issues account for the majority of elevator service calls and TSSA deficiencies in Ontario. During every monthly visit, the technician should be inspecting and adjusting the door operator — the motorized mechanism that opens and closes the car doors. This includes checking the operating speed, the closing force, and the smooth engagement of the operator arms and linkages. The car and hall door rollers should be inspected for wear and replaced as needed. Door gibs — the guides that keep the doors tracking straight — wear down over time and need regular checking and replacement. The sill grooves at every landing should be cleaned of debris and inspected for wear, because worn sill grooves allow doors to drift out of alignment.
Door safety devices need monthly testing. This includes the light curtain or safety edge that detects obstructions in the doorway, the door reopening circuit, and the nudging feature that allows the doors to close at reduced force after the safety timer expires. In buildings that serve seniors, people with disabilities, or high volumes of wheeled traffic like hospitals or retirement communities, door timing and sensitivity settings should be checked against the needs of the specific population using the elevator.
The technician should ride the elevator through its full range of travel during every monthly visit, paying attention to ride quality — any unusual vibrations, noises, rough starts or stops, or jerking motions. They should check levelling accuracy at every floor: when the car stops, is it exactly level with the landing, or is there a gap? Levelling issues can develop gradually as components wear, and catching them early prevents the problem from becoming a safety hazard or a complaint generator.
In the machine room (or the controller compartment for machine-room-less installations), the technician should be performing a visual inspection of all major components, checking for signs of overheating, loose connections, unusual wear, fluid leaks (on hydraulic systems), and any abnormal conditions. They should check the oil level and condition in the door operator and, on hydraulic systems, check the hydraulic fluid level and look for any signs of leaks in the tank, piping, or cylinder.
The car interior and fixtures should be inspected monthly. This includes testing the emergency communication device (phone or intercom), checking the operation of all car buttons and indicators, verifying that the car lighting is functioning properly, and noting any damage to the car interior that might indicate abuse or impact damage.
The pit should be checked for water intrusion, debris, and the condition of pit-mounted equipment including the buffer springs or oil buffers, the car and counterweight (on traction systems) guide shoes or rollers, and the pit stop switch. Water in the pit is a common problem in Ontario, particularly during spring thaw and after heavy rains, and it can cause corrosion, electrical faults, and hydraulic contamination if not addressed.
All monthly maintenance activities should be documented in the machine room log book with specific notes about what was inspected, what was adjusted, and any conditions that need follow-up. If your log book entries say nothing more than “routine maintenance performed,” that’s a warning sign that the technician may not be doing substantive work.
Quarterly Maintenance Tasks
Quarterly maintenance builds on the monthly program with more detailed inspections and tests that don’t need to happen every month but are essential for catching problems that develop on a slower timeline.
On traction elevator systems, quarterly maintenance should include a detailed inspection of the wire ropes (hoist cables). The technician should examine the ropes for broken wires, corrosion, uneven wear, and proper tension equalization. Rope deterioration happens gradually, and quarterly inspections allow the technician to track the rate of wear and plan for replacement before the ropes reach the point where they’d fail a TSSA inspection. The sheaves (the pulleys that the ropes ride on) should also be inspected for groove wear, which can accelerate rope deterioration if not addressed.
On hydraulic systems, the quarterly check should include a more detailed assessment of the hydraulic power unit. This means checking the pump motor and pump for unusual noise or vibration, inspecting the control valves, checking the hydraulic fluid for contamination or degradation, and verifying that the system is operating at the correct pressure. The hydraulic cylinder and piston should be inspected for signs of drift — if the elevator slowly settles downward when it’s supposed to be stationary at a floor, the piston seals or control valves may be wearing. Slight drift might not be noticeable to passengers on a daily basis, but a technician who tracks it quarterly can identify a developing seal problem before it becomes a failure.
The guide rails and guide shoes (or guide rollers) should receive a quarterly inspection. These components are responsible for keeping the elevator car and counterweight tracking smoothly in the hoistway, and wear in this area manifests as ride quality degradation — vibrations, side-to-side movement, or noise that passengers notice. Guide shoe inserts or guide roller bearings have a finite life and need to be replaced before they reach the point of metal-to-metal contact with the guide rails.
Governor and safety device inspection is a quarterly task on traction systems. The governor is the speed-sensing device that triggers the car safety in the event of an overspeed condition — it’s one of the most critical safety components on the elevator. The governor should be inspected for proper operation, correct rope tension, and the condition of the governor rope. While the car safety itself is tested annually (more on that below), the governor’s intermediate condition should be monitored quarterly.
Electrical connections throughout the system should receive a quarterly check. This includes controller terminal tightness, relay and contactor condition, motor connections, and the connections at the traveling cable — the flexible cable that runs from the car to the controller and carries power and signals. Loose connections generate heat, which can cause intermittent faults, component damage, and in extreme cases, electrical fires. A thorough quarterly check of electrical connections is one of the most effective ways to prevent intermittent, hard-to-diagnose malfunctions.
The ventilation and climate conditions in the machine room or hoistway should be reviewed quarterly, with attention to seasonal changes. In Ontario, summer heat can cause machine room temperatures to rise to levels that affect controller performance and motor life. Winter cold can affect hydraulic oil viscosity and cause condensation issues. A technician who is paying attention to these environmental factors and making seasonal adjustments — or recommending building improvements like machine room ventilation — is providing a level of service that directly extends equipment life.
Annual Maintenance Tasks
Annual maintenance includes the major testing and inspection tasks that verify the safe operation of critical safety systems and the overall condition of the equipment. Many of these tests are also required by the TSSA for compliance purposes, so they serve a dual role of ensuring safety and meeting regulatory obligations.
The annual safety test on a traction elevator is the most significant annual maintenance event. This test verifies the operation of the overspeed governor and car safety — the devices that physically stop the car in the event of a free-fall or overspeed condition. The test involves intentionally triggering the governor and verifying that the car safety engages properly, gripping the guide rails and bringing the car to a controlled stop. This test must be performed by a licensed elevator contractor and the results documented for TSSA review. It’s a test that, if failed, indicates a serious safety deficiency that needs immediate remediation.
On hydraulic systems, the annual maintenance should include a pressure relief valve test to verify that the system’s maximum pressure is within design limits, and a check of the plunger and cylinder condition. For buried hydraulic cylinders — which are common in older Ontario installations — the annual assessment should include evaluation of the cylinder’s external condition to the extent possible, including monitoring for any signs of underground leakage.
A comprehensive hoistway inspection should be performed annually. This goes beyond the visual checks performed during monthly and quarterly visits and includes a detailed examination of the hoistway structure, the hoistway door interlocks at every landing, the condition of the guide rails, rail brackets, and fastenings, and the clearances at the top and bottom of the hoistway. The technician should be verifying that the overhead clearance above the car (the “overrun” space) and the pit depth below the car’s lowest travel meet code requirements — these dimensions can change if the building structure settles or if modifications have been made in the hoistway or pit.
All fire service features should receive a comprehensive annual test. This includes Phase I (automatic elevator recall on fire alarm activation) and Phase II (firefighters’ emergency operation from within the car). These tests should involve coordination with the building’s fire alarm system to verify that the elevator responds correctly to fire alarm signals, and a physical test of all Phase II functions from inside the car. In Ontario, TSSA inspectors will specifically check fire service operation during their periodic inspections, and deficiencies in this area are treated seriously.
The annual maintenance visit is also the appropriate time for a comprehensive assessment of the elevator’s overall condition and a forward-looking discussion with the building owner about expected repair needs, capital planning, and any recommended upgrades or modernization considerations. This is where the relationship between the building owner and the maintenance contractor is most valuable. A contractor who provides an honest, detailed annual condition assessment — including the news you might not want to hear about aging components or upcoming expenses — is worth far more than one who just keeps billing you for monthly visits without ever looking at the big picture.
How to Use This Checklist
This checklist is meant to be a tool, not a weapon. The goal isn’t to micromanage your elevator technician — good technicians are professionals who take pride in their work and don’t need someone looking over their shoulder on every task. The goal is to give you enough knowledge to have meaningful conversations about what’s being done, to recognize when something is being neglected, and to set appropriate expectations for the level of service your building needs.
Here are some practical ways to use this information. First, review your maintenance contract against this checklist. Does the contract specify the frequency of visits? Does it describe the scope of work at each visit, or does it simply say “preventive maintenance” without defining what that means? If the scope is vague, you don’t have a meaningful basis for holding the contractor accountable. Second, periodically check the machine room log book and compare the entries against the tasks described here. A log that consistently shows specific, detailed work being performed is a good sign. A log with sparse, generic entries — or worse, missing entries — should prompt a conversation with your contractor.
Third, pay attention to results. The most important metric for evaluating maintenance quality isn’t how many hours the technician spends on-site — it’s how reliably your elevator performs. Track your service call frequency. Track your TSSA inspection results. Track tenant or resident complaints about ride quality, door behaviour, or noise. These outcome metrics tell you more about the quality of your maintenance program than any checklist ever could. If you’re experiencing frequent breakdowns, recurring TSSA deficiencies, or persistent ride quality complaints, the maintenance program isn’t working — regardless of what the log book says.
And finally, don’t hesitate to ask questions. A good elevator contractor will welcome informed questions from building owners because it shows that you care about your equipment and are willing to invest in its proper care. If your contractor is evasive, defensive, or dismissive when you ask about specific maintenance activities, that tells you something important about the relationship and whether it’s serving your building’s interests.